dIagnoStIcS -

delIvery StatuS

delIvery StatuS

A series of yes/no questions to help diagnose any errors occurring on the LCR 600.

ROM Check Sum?

Display Only

Has a fueling not started due to the checksum of the

LectroCount program code space failing?

Temperature?

Display Only

Has the current fueling not started (or was terminated) due to

an error with the temperature reading hardware?

Watchdog?

Display Only

Was the processor reset due to a LectroCount watchdog time

out error?

VCF Setup?

Display Only

Was there an error setting up the volume compensation factor

for the current product?

VCF domain?

Display Only

Did the temperature of the product go outside the valid range for the compensation type of the product?

Meter Calibration?

Display Only

Did an error occur while setting up the flowmeter calibration for the current fueling?

Pulser Failure?

Display Only

Did the current fueling terminate due to too many pulser faults?

Preset Stop?

Display Only

Was the gross or net preset volume reached?

No-Flow Stop?

Display Only

Was the current fueling stopped due to no-flow being detected through the flowmeter for a specified amount of time?

Stop/Pause Request?

Display Only

Was a stop activated by the selector switch during an active fueling?

Print/end Request?

Display Only

Was a print activated by the selector switch during an active fueling?

Power Failure?

Display Only

Did a fueling end due to a power fail condition for more than 15 seconds?

Preset error? D

isplay Only

Did a fueling end due to an error condition while attempting to set up a gross or net preset?

Printer?

Display Only

Does the current fueling require a printed ticket but the printer is off-line or busy?

data Access?

Display Only

Did a data access error occur during the fueling which was critical to the fueling?

Next/Previous Screen

D E L I V E R Y S T A T U S

ROM Check Sum?

Temperature?

Watchdog?

VCF Setup?

VCF Domain?

Meter Calibration?

Pulser Failure?

Preset Stop?

No-Flow Stop?

Stop/Pause Request?

Print/End Request?

Power Failure?

Preset Error?

RS-232 Lap Pad?

Printer?

Data Access?

NO

NO

NO

NO

NO

NO

NO

NO

NO

NO

NO

NO

NO

NO

YES

NO