Setup, Preparing for calibration, Calibration setup – Liquid Controls FlightConnect 600 User Manual
Page 22

22
Setup -
calIbratIon Setup
preparing for calibration
Before the LCR 600 is put into daily operation, the register must be defined and proved according to the liquid that
the flowmeter will be measuring. This is done in the Calibration Setup screens. Although the LCR 600 can hold a
total of 16 different calibrations simultaneously, FlightConnect is designed for only one calibration (Calibration #1). In
FlightConnect, the primary purpose of the Calibration Setup screens is to calibrate Product 1 of the LCR 600.
to calibrate an lcr 600
1. Remove the switchplate and move the selector switch to the calibration position.
2. Enter the proper settings in Calibration Setup 1 and Calibration Setup 2.
3. Prove the flowmeter system with single-point or multi-point calibration.
calIbratIon Setup 1
Calibration #:
(LB)
c - u - l
flightconnect
The active calibration of 16 possible calibrations. The fields shown
on the Calibration Setup 1 screen represent the values of the
Calibration # shown. Any edits made to the fields are attributed
to the
Calibration # shown. FlightConnect only uses Calibration
#1.
Calibration Code:
(tB)
c - u
flightconnect
The code assigned to the active calibration. This code can be used
to correspond with an office code. A value in this field is not required
for FlightConnect.
Calibration Name:
(tB)
c - u
flightconnect
The text designation of the active calibration. A value in this field is not required for FlightConnect.
Calibration Type:
(LB)
c
flightconnect
The product type of the active calibration.
Aviation is the preferred FlightConnect setting.
Ammonia • Aviation • Distillate • Gasoline • Methanol • LPG • Lube Oil • blank
Linearization Mode:
(LB)
c
Disables and enables single and multi-point calibration.
Setup allows the setting of single and multi-point calibration. Disables single and multi-point calibration settings in fuelings.
Applied enables multi-point calibration settings in fueling.
Pulses/Unit
(tB)
c
The number of pulse edges per unit of measure. Applies only to gross volume. This number scales the prover
quantity. A unit of 20.0000 is entered on all factory shipments. Changing the k-factor moves the entire flowmeter
accuracy curve either up or down. See table on page 26.
Prover Quantity:
(tB)
c
The metered volume of the prover after a calibration fueling. When the prover volume is entered, the LCR 600 adjusts
the k-factor to calibrate the pulses/unit. See calibration instructions.
BEGIN CALIBRATION DELIVERY
Starts a calibration fueling. See page 25.
S1 Close:
(tB)
c
flightconnect
The point during a preset fueling when the valve switches from full flow to a dwell flow. The LCR 600 will switch the
valve to dwell flow when the volume remaining in the preset fueling reaches the value of this field. 0 to 500 range.
0
is the preferred FlightConnect setting (aviation flowmeter systems typically do not have two-stage valves, which are
required for this feature).
Net Totalizer:
Display only
c
Total accumulated net (temperature compensated) volume delivered by the LCR 600. In the calibration position, this
field can be set to any positive value. The value resets after a clear all.
Gross Totalizer:
Display only
c
Total accumulated gross volume delivered by the LCR 600. In the calibration position, this field can be set to any
positive value. The value resets after a clear all.
Calibration #: 1
Calibration Code:
Calibration Name:
Calibration Type:
Linearization Mode:
Pulses/Unit:
Prover Quantity:
BEGIN CALIBRATION DELIVERY
S1 Close
Net Totalizer
Gross Totalizer
Gallons
Aviation
Setup
20.0000
00 Gallons
2.0 Gallons
0.0 Gallons
141.7 Gallons
C A L I B R A T I O N S E T U P
Next/Previous Screen
1
tB - text Box
LB - List Box
field type