Setup, Preparing for calibration, Calibration setup – Liquid Controls FlightConnect 600 User Manual

Page 22

background image

22

Setup -

calIbratIon Setup

preparing for calibration

Before the LCR 600 is put into daily operation, the register must be defined and proved according to the liquid that

the flowmeter will be measuring. This is done in the Calibration Setup screens. Although the LCR 600 can hold a

total of 16 different calibrations simultaneously, FlightConnect is designed for only one calibration (Calibration #1). In

FlightConnect, the primary purpose of the Calibration Setup screens is to calibrate Product 1 of the LCR 600.

to calibrate an lcr 600

1. Remove the switchplate and move the selector switch to the calibration position.
2. Enter the proper settings in Calibration Setup 1 and Calibration Setup 2.
3. Prove the flowmeter system with single-point or multi-point calibration.

calIbratIon Setup 1
Calibration #:

(LB)

c - u - l

flightconnect

The active calibration of 16 possible calibrations. The fields shown

on the Calibration Setup 1 screen represent the values of the

Calibration # shown. Any edits made to the fields are attributed

to the

Calibration # shown. FlightConnect only uses Calibration

#1.

Calibration Code:

(tB)

c - u

flightconnect

The code assigned to the active calibration. This code can be used

to correspond with an office code. A value in this field is not required

for FlightConnect.

Calibration Name:

(tB)

c - u

flightconnect

The text designation of the active calibration. A value in this field is not required for FlightConnect.

Calibration Type:

(LB)

c

flightconnect

The product type of the active calibration.

Aviation is the preferred FlightConnect setting.

Ammonia • Aviation • Distillate • Gasoline • Methanol • LPG • Lube Oil • blank

Linearization Mode:

(LB)

c

Disables and enables single and multi-point calibration.

Setup allows the setting of single and multi-point calibration. Disables single and multi-point calibration settings in fuelings.
Applied enables multi-point calibration settings in fueling.

Pulses/Unit :

(tB)

c

The number of pulse edges per unit of measure. Applies only to gross volume. This number scales the prover

quantity. A unit of 20.0000 is entered on all factory shipments. Changing the k-factor moves the entire flowmeter

accuracy curve either up or down. See table on page 26.

Prover Quantity:

(tB)

c

The metered volume of the prover after a calibration fueling. When the prover volume is entered, the LCR 600 adjusts

the k-factor to calibrate the pulses/unit. See calibration instructions.

BEGIN CALIBRATION DELIVERY

Starts a calibration fueling. See page 25.

S1 Close:

(tB)

c

flightconnect

The point during a preset fueling when the valve switches from full flow to a dwell flow. The LCR 600 will switch the

valve to dwell flow when the volume remaining in the preset fueling reaches the value of this field. 0 to 500 range.

0

is the preferred FlightConnect setting (aviation flowmeter systems typically do not have two-stage valves, which are

required for this feature).

Net Totalizer:

Display only

c

Total accumulated net (temperature compensated) volume delivered by the LCR 600. In the calibration position, this

field can be set to any positive value. The value resets after a clear all.

Gross Totalizer:

Display only

c

Total accumulated gross volume delivered by the LCR 600. In the calibration position, this field can be set to any

positive value. The value resets after a clear all.

Calibration #: 1

Calibration Code:

Calibration Name:
Calibration Type:
Linearization Mode:
Pulses/Unit:

Prover Quantity:

BEGIN CALIBRATION DELIVERY
S1 Close
Net Totalizer

Gross Totalizer

Gallons

Aviation

Setup

20.0000

00 Gallons

2.0 Gallons
0.0 Gallons

141.7 Gallons

C A L I B R A T I O N S E T U P

Next/Previous Screen

1

tB - text Box

LB - List Box

field type