23

calIbratIon Setup

- Setup

calIbratIon Setup 2
Calibration #:

(LB)

c - u - l

flightconnect

The active calibration of 16 possible calibrations. The fields shown

on the Calibration Setup 2 screen represent the values of the

Calibration # shown. Any edits made to the fields are attributed to

the

Calibration # shown. FlightConnect only uses Calibration #1.

Compensation Type:

(LB)

c

The type of temperature volume compensation applied to the active

Calibration #. Refer to the Compensation Types and Parameters

table on page 27 to find the correct compensation. If

NoNe is selected,

fuelings will be in gross quantities only.

Linear F • Linear C • API Table 24 • API Table 54 • API Table 6B • API Table 54B •

API Table 54C • API Table 54D • NH3 • NONE

Compensation Parameter:

(tB)

c

The coefficient of expansion, the standard density, API gravity, or the specific gravity applied to the

Compensation

Type. This field has default values that are set when Compensation Type changes. Ensure the default value is

correct. Refer to the Compensation Types and Parameters table on page 27 for ranges.

Base Temperature:

(tB)

c

The base temperature for temperature compensated fuelings. Although this field is editable for some

Compensation

Type values, it defaults to 60°F or 15°C according to the selected Compensation Type.

Gross Quantity:

Display only

The gross volume of the latest calibration fueling.

Gross Preset:

(tB)

c - u - l - p

The gross preset for the next calibration fueling.

Temperature:

Display only

The current temperature reading of the RTD temperature probe.

Net Quantity:

Display only

The net volume of the latest calibration fueling.

Auxiliary Multiplier:

(tB)

c

The factor used to convert the measured volume of a fueling to an alternate volume or mass unit. If this field is 0, it will

not print on the fueling ticket. Users must furnish a conversion factor.

example

auxiliary multiplier = (Spgr) x (8.345 Ibs/gal)

SpGr = specific gravity

Auxiliary Quantity:

(tB)

c

The alternate volume or mass delivered using the

Auxiliary Multiplier.

Auxiliary Unit of Measure:

(LB)

c

The auxiliary unit of measure printed on the fueling ticket.

Gallons • Litres • Cubic M • LBS • KGS • Barrels • Other

Calibration #: 1
Compensation Type:

Comp Parameter:

Base Temperature:
Gross Quantity:

Gross Preset:
Temperature:

Net Quantity:
Auxiliary Mult:

Auxiliary Quantity:

Auxiliary Unit/Measure:

Gallons

None

----------

----

11.5 Gallons

0.0 Gallons

74.7

11.2

0.000

0

Litres

C A L I B R A T I O N S E T U P

Next/Previous Screen

2

l - locked
u - unlocked
c - Weights & measures calibration
p - Stop/pause
f - factory

Security clearance

The fields on the Calibration Setup 2 screen are used

to define temperature compensation parameters for

flowmeter systems with ETVC kits installed. Fields

should be left blank for systems without ETVC.

flightConnect & temperature Compensation