Viewing local alarm history – ADC Campus-REX2 RS User Manual
Page 91

Chapter 5 - Monitoring and Testing the Campus System
Campus-REX2 RS Interface Card User Manual
79
Viewing Local Alarm History
This screen displays alarm history information. From the System Status
Menu, type
then press
. The Local Alarm History screen is
displayed.
This screen shows alarm history of the local unit. If the HDSL line uses two
loops, the screen includes information for both loops. The screen includes
information on the following alarms:
•
Errored seconds (ES) for HDSL loop A (first pair) and HDSL loop B
(second pair, when applicable)
•
Margin for HDSL loop A (first pair) and HDSL loop B (second pair,
when applicable)
•
Loss of Signal (LOS) for the HDSL port
To view remote alarm history, type
then press
.
To update the information, type
then press
.
To clear the information, type
then press
.
Alarm history information is lost when power is removed from
the Campus unit.
4
ENTER
Jul 07, 2003
ADC TELECOMMUNICATIONS, CAMPUS RS, Version 5.1 08:19:34
Local Unit ID:
Local I/F:
REX2
Remote Unit ID: Inactive
Remote I/F: Inactive
Circuit ID:
LOCAL ALARM HISTORY
Type
Current
First
Last
Count
HDSL Link,
ACTIVE
Dec 09, 1999-04:30:03
Nov 31, 1999-12:21:01
1
ES,
HDSL-A
OFF
0
ES,
HDSL-B
OFF
0
Margin, HDSL-A
OFF
0
Margin, HDSL-B
OFF
0
LOS,
Port
OFF
0
Last Cleared:
None
(S)witch to Remote Alarm History
(U)pdate
(C)lear
(R)eturn
(M)ain Menu
ENTER CHOICE>
S
ENTER
U
ENTER
C
ENTER