5

Charged batteries

in storage ports

Battery in

charging port

Empty

charging ports

BATTERY CHARGER SETUP

IMPORTANT! – Before installing the system, connect the AC power supply to the AC40A Battery Charger
and plug it into an electrical outlet. Charge all the batteries while the other equipment is being installed.
Charging time is about 2.5 hours.

Connect AC Power Supply

Attach the AC power supply cable connector to the screw connector on the battery charger.
Plug the power cord connector into the AC power supply.
Plug the power cord into an electrical outlet.

The red lights on the charger will come on and go off, and then the yellow lights will come on and stay on.

Charge Batteries

Up to four batteries can be charged in the battery charger at
the same time. The battery status lights next to each
charging port are explained below. Up to six fully charged
batteries can be stored in the battery storage ports.
Insert a battery in each of four charging ports until it

clicks in place.

A yellow light next to each charging port stays on while

the port is empty. When a battery is in a charging port, a
flashing yellow light next to it indicates CHARGE
PENDING, which means the battery is too hot. Adjust
the room temperature or move the charger to a cooler
area. When a battery is in a charging port, a yellow light
on steady next to it means CHARGE FAILED.
If this happens, follow the instructions on the side of
battery charger.

A red CHARGING light next to a battery port stays on

while a battery in the port is charging.
A green READY light next to a battery port goes on
when a battery in the port is fully charged.

Store fully charged batteries in storage ports.
NOTE: The storage ports neither charge nor maintain the

batteries. They simply provide a place to store the
charged batteries until they are needed.

Batteries should not be left in charge ports after being fully
charged. If a battery is left in a charge port for more than
three weeks, the yellow indicator may light up. In this case, it does not indicate a faulty battery.