beautypg.com

Technical data, Equipment specifications, Base station – Clear-Com HME DX100 User Manual

Page 33: Section 5, Q ipment specifications, Base s, Tation

background image

29

SECTION 5. TECHNICAL DATA

E U

Base S

Q IPMENT SPECIFICATIONS

tation

GENERAL

0 to 2483.5 MHz

VDC

cm)

Any 4 can have simultaneous full-duplex communication at one time.

Others would be listen-only until a channel becomes available.

TRANSM

Type:

Frequency hopping, spread spectrum

100mW burst

REC

Frequency hopping, spread spectrum

Frequency Range:

All, 240

Low, 2401.92 to 2439.94 MHz

High, 2443.39 to 2481.41 MHz

Frequency Response:

200 Hz to 3.5 kHz

Power Requirements:

100-240VAC, 50-60Hz or 12-14

Temperature Range:

32-122°F (0-50°C)

Size:

10.2” x 6.45” x 3.33” (1-RU) (25.91 x 16.38 x 8.46

Weight:

2.35 lbs. (1.07 kg) maximum

# of Beltpacs per Base:

15 can be registered

Front Panel Controls:

Power, Register Beltpac, Reset, Unlatch and Clear/Band buttons

LEDs

Front Panel Indicators:

Registration Status display, Power and Receive

Antenna Type:

External ½ -wave dipole (R-TNC connector)

RX/TX horizontal/vertical diversity

System Distortion:

<2%

Communication Security:

64-bit encryption dual-slot diversity

Splash Resistant:

IEC529 IP Code 4 (under battery operation only)

ITTER

Transmit Power:

Modulation Type:

Gaussian filtered FSK, TDM

Frequency Stability:

13 ppm

Harmonics/Spurious:

Exceeds FCC and ETSI specifications over temperature

EIVER

Type:

RF Sensitivity:

<

−90dBm w 10

-3

BER

Frequency Stability:

13 ppm

Distortion:

<2%