beautypg.com

Troubleshooting – GF Signet 8350 Temperature Transmitter User Manual

Page 8

background image

Troubleshooting

Georg Fischer Signet LLC, 3401 Aero Jet Avenue, El Monte, CA 91731-2882 U.S.A. • Tel. (626) 571-2770 • Fax (626) 573-2057
For Worldwide Sales and Service, visit our website: www.gfsignet.com • or call (in the U.S.): (800) 854-4090
For the most up-to-date information, please refer to our website at www.gfsignet.com

3-8350.090-3 Rev. J 01/13 English

© Georg Fischer Signet LLC 2013

Ordering Information

Mfr. Part No.

Code

Description

3-8350-1

159 000 192

Temperature transmitter Field mount

3-8350-1P

159 000 193

Temperature transmitter Panel mount

3-8350-2

159 000 194

Temperature transmitter Field mount with relays

3-8350-2P

159 000 195

Temperature transmitter Panel mount with relays

3-8350-3

159 000 196

Temperature transmitter Field mount with dual input/output

3-8350-3P

159 000 197

Temperature transmitter Panel mount with dual input/output

Accessories

Mfr. Part No.

Code

Description

3-8050

159 000 184

Universal mounting kit

3-8052

159 000 188

3/4 in. Integral mounting kit

3-8052-1

159 000 755

3/4 in. NPT mount junction box

3-8050.395

159 000 186

Splashproof rear cover

3-8050.396

159 000 617

RC Filter kit (for relay use)

3-0000.596

159 000 641

Heavy duty wall mount bracket

3-5000.598

198 840 225

Surface Mount Bracket

3-9000.392

159 000 368

Liquid tight connector kit for rear cover (includes 3 connectors)

3-9000.392-1

159 000 839

Liquid tight connector kit, NPT (1 piece)

3-9000.392-2

159 000 841

Liquid tight connector kit, PG13.5 (1 piece)

3-9900.396

159 001 701

Angle Adjustment Adapter Kit

Display Condition

Possible Causes

Suggested Solutions

Check Sensor?

• Sensor not wired properly.
• Sensor connected to 8350 while power

is on.

• Defective sensor.

• Correct sensor wiring.
• Recycle power with all sensors connected.
• Replace defective sensor.

Too much error

CHECK SENSOR

The value entered in Set Temperature
fi eld is greater than 20 °C (36 °F)
deviation from sensor input. (The 8350
allows a maximum of 20 °C offset.).

• Confi rm calibration values.
• Enter -999 in Set Temperature fi eld.
• Replace defective sensor.

Reset to Factory

Calibration

Value in SET TEMPERATURE fi eld
is -999.

Entering "-999" in this fi eld will remove all user
calibration input and restore the factory values.

Open Collector is always

activated

Hysteresis value too large.
Defective transmitter.

Change the hysteresis value
Replace transmitter

Value must be

400 or less

Value entered in Output PlsRate fi eld is
greater than 400.

Select a maximum pulse rate of 400 pulses per
minute or less.

SETUP READ ERROR

Press Any Key

Memory fault occurred.

• Press any key to reload factory presets.
• Reprogram all setpoints.
• If this message appears again, replace the

8350.