Specifi cations – GF Signet 2540 Stainless Steel High Performance Flow Sensor User Manual
Page 10
![background image](/manuals/331049/10/background.png)
2540 High Performance Flow Sensor
10
04/08
10. Specifi cations
General Data
Flow velocity range:
0.1 to 6 m/s (0.3 to 20 ft/s)
Linearity:
±1% of full range
Repeatability:
±0.5% of full range
Pipe range:
•
Standard version:
38 to 610 mm (1.5 to 24 in.)
•
Hot-Tap version:
38 to 914 mm (1.5 to 36 in.)
Sensor fi tting options:
316 SS with 1.5 in. NPT threads,
OR 316 SS with IS0 7-R
1½
threads
Cable length:
7.6 m (25 ft), can splice up to
300 m (1000 ft)
Cable type:
2-conductor twisted-pair with
22
AWG
shield
Electrical Data
Supply voltage:
5 to 24 VDC
Supply current:
1.5 mA max.
Output type:
Open collector, sinking
Output current:
10.0 mA max.
Wetted Materials
Sensor body:
316 stainless steel
Sensor fi tting:
316 stainless steel
Sensor fi tting O-rings:
Standard FPM, optional EPDM
Rotor:
CB7 Cu-1 alloy 17-4 per AMS5355H
Rotor shaft:
Tungsten carbide (standard)
316 stainless steel (option)
Shaft retainers (2):
316 stainless steel
Rotor bearings (2):
Carbon fi ber reinforced PTFE
Quality Standards
•
Manufactured under ISO 9001 for Quality, ISO 14001
for Environmental Management and OHSAS 18001 for
Occupational Health and Safety.
China RoHS (Go to www.gfsignet.com for details)
This device complies with Part 15 of the FCC rules
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and,
(2) This device must accept any interference
received, including interference that may cause
undesired
operation.
Standard Sensor Dimensions:
• 2540-1(S) = 1½ in. NPT fi tting
• 2540-2(S) = IS0 7-R 1½ fi tting
Hot-Tap Sensor Dimensions:
• 2540-3(S) = 1½ in. NPT fi tting
• 2540-4(S) = IS0 7-R 1½ fi tting
457 mm
(18 in.)
Adjustable
length
Sensor fitting:
1½ in. NPT or
ISO 7-R 1½ thread
24 mm (0.94 in.) dia.
64 mm (2.5 in.) dia.
Bleed
valve
7.6 m
(25 ft.)
cable
O-ring
seals (2)
Adjustable
length
7.5 m (25 ft.)
integral cable
24 mm (0.94 in.) dia.
64 mm (2.5 in.) dia.
127 mm
(5.0 in.)
Sensor fitting:
1½ in. NPT or
ISO 7-R 1½ thread
O-ring
seal (1)
Caution: The 2540 Hot-Tap system's overall
specifi cations and limitations depend on the lowest
maximum rating of the components associated with the
system. In other words, the Hot-Tap system is only as
strong as its weakest link. For example, a ball valve, a
component of the system, is rated at a maximum 100 psi @ 175°F,
limiting the entire system's maximum pressure/temperature rating
to 100 psi @ 175°F. All higher maximum specifi cations MUST
yield to the component with the lowest maximum specifi cation.
Fluid Conditions
Maximum operating pressure/temperature:
• Sensor with standard FPM sensor fi tting O-rings:
17 bar (250 psi) @ 82°C (180°F)
• Sensor with optional EPDM sensor fi tting O-rings:
17 bar (250 psi) @ 100°C (212°F)
Note: Pressure/temperature specifi cations refer to sensor
performance in water. Certain chemical limitations may apply.
Chemical compatibility should be verifi ed.
manufactured date code = mm/yy
ex. 04/08
04 - month of April
08 - year 2008