Configuring the electric network frequency, Parameterizing the cut-off flow rate – Burkert Type 8045 User Manual
Page 55

51
Operatingandfunctions
8.6.15. configuring the electric network frequency
This	parameter	makes	it	possible	to	configure	the	electric	network	frequency	so	that	the	device	can	filter	the	inter-
fering	signals	of	the	power	supply.
Adjust this parameter even if the device operates with a DC voltage.
FREqUENC.
F = 50hz
CUt-OFF
0......9
→
Choose the electric network frequency.
→
Confirm
F = 60hz
Fig. 51:
Diagram of the "FREQUEnC." parameter of the Parameters menu
→
If you do not want to adjust another parameter, go to the "END" parameter of the Parameters menu and press
ENTER
to save the settings or not and go back to the Process level.
8.6.16. parameterizing the cut-off flow rate
This	parameter	makes	it	possible	to	set	the	flow	rate	value	to	0	if	the	measured	value	is	less	than	the	set	cut-off	
value:
• the display then shows a flow rate = 0 (a dot is displayed after the flow rate units).
• the outputs and the totalizers react as if the actual flow rate was = 0.
CUt-OFF
CO=0.000
BACKLit
→
Enter	the	measured	flow	rate	value	below	which	the	device	considers	that	the	flow	rate	
is	=	0.
→
To disable the function, set CO=0.
→
Confirm
Fig. 52:
Diagram of the "CUT-OFF" parameter of the Parameters menu
→
If you do not want to adjust another parameter, go to the "END" parameter of the Parameters menu and press
ENTER
to save the settings or not and go back to the Process level.