14
Technicaldata
10
9
8
7
6
5
4
3
2
1
0
0
+20
+40
+60
+80
PVDF (PN10) /
PP (PN10)
P (bar)
PVC + PP
A
PVC (PN10)
T (°C)
Metal
8045 with flow sensor in PVDF
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
-20
0
+20 +40 +60 +80 +100 +120
PVDF (PN10)
PVC (PN10)
PP (PN10)
T (°C)
P (bar)
PVC + PP
PVDF
A
DN100 for measuring
devices with a clamp con-
nection (PN10)
Metal
(PN16)
1)
1)
Except DN100 for measuring devices with a clamp connection
8045 with flow sensor in stainless steel
A: range of use
Fig. 6:
Fluid pressure /temperature dependency for a 8045 with PVDF flow sensor or stainless steel flow sensor and
a fitting S020 in metal, PVC, PVDF or PP
6.3.2.
General data
Pipe diameter
DN6 to DN400
Type of fitting
S020
Min. fluid conductivity
20 µS/cm
fluid temperature
• 8045 with flow sensor in PVDF
• 8045 with flow sensor in stainless steel
The fluid temperature may be restricted by the fluid
pressure, the material the flow sensor is made of and
the material the S020 fitting used is made of. See “Fig.
6”.
• 0 to +80 °C
• -15 to +110 °C
Fluid pressure
• 8045 with flow sensor in PVDF
• 8045 with flow sensor in stainless steel
The fluid pressure may be restricted by the fluid
temperature, the material the flow sensor is made of,
the material the S020 fitting used is made of and the
DN of the S020 fitting. See “Fig. 6”.
• PN10
• PN16
English