Details of the parameters menu – Burkert Type 8045 User Manual
Page 35

31
Operatingandfunctions
8.6.
Details of the parameters menu
To access the Parameters menu, simultaneously press keys
ENTER
for at least 5
s.
This menu comprises the following configurable parameters:
LANGUAGE
Process level
UNit
K-FACtOR
OUtPUt
iNPUt
FiLtER
tOtAL
FREqUENC.
CUt-OFF
BACKLit
12.6 L/s
END
0......9
Choosing the display language
sAVE N/Y
Choosing	the	flow	rate	unit,	the	number	of	decimals	and	the	unit	the	totalizers	are	
displayed	in.
Entering	the	K	factor	of	the	fitting	used	or	have	it	defined	through	a	teach-in	
procedure.	
Parameterize	the	4-20	mA	current	output	(AO1)	and	configure	the	transistor	output	
(DO1)	and,	if	the	device	is	equipped	with,	the	2	relay	outputs	(DO2	and	DO3).
Configuring the ON/OFF digital input (DI1), if the device is equipped with.
Choosing	the	filter	level	of	the	measured	flow	rate,	on	the	displayed	flow	rate	and	the	
AO1	current	output.
Resetting both totalizers.
Setting the electric network frequency.
Entering	the	measured	flow	rate	value	below	which	the	device	sets	the	measured	flow	
rate	to	0	with	effect	on	the	display	and	the	outputs.
Setting	the	brightness	of	the	display	and	how	long	it	stays	ON,	or	deactivating	the	
backlight.
Saving	the	changes	made	within	the	Parameters	
menu	or	not.	If	the	changes	are	saved,	the	device	
operates	with	the	new	settings.
Fig. 26:
Diagram of the Parameters menu