3.
SD CARD / SYSTEM SERIALIZATION DATA
The serialization data of completely installed systems of type 8650 can be provided as a data record.
The record includes the serial numbers of the valves, the electronic modules and the terminal module. The order
always refers to the system configuration from left to right (serial number of the valve island – serial number of all
electronic modules – serial number of all valves – serial number of all terminal modules)
The structure of a serialization data record is provided as an example in the chapter; Commissioning /
SD-card / System Serialization Data / Serialization Data Record
The data record is on an sd-card, which is located in the storage compartment of the pressure gauge module.
The data is in common .xml format and can be easily worked on (i.e. for your facilities records) using a variety of
tools (e.g. a simple text editor, browsers or a spreadsheet program).
3.1.
Serialization Data Record
The following is an example of the structure of a serialization data record.
Type 8650
english
Commissioning