Pneumatic connections, Accessory, . pneumatic.connections – Burkert Type 8650 User Manual
Page 45: . accessory
45
NOTE!
Pressure.supply!
When using the P shut-off basic modules, ensure that the pressure supply to the valve islands is
configured with a sufficiently large volume. (Minimum hose diameter 8/6 mm)
4.2.4.
Overview
3
5
6
7
8
9
2
1
4
Legend
1
2
3
4
5
6
7
8
9
check valve (optional)
Labeling of valve positions and installed
options
Inclined tie rods
Service ports
(assignment dependant on valve type)
Flange for valve
P shut-off (optional, only for certain versions)
X channel
R- & S channel
P channel
Fig. 16: Overview - Basic pneumatic module (Station width: 44 mm, with the options check valves and P shut-off)
4.3.
Pneumatic Connections
1
2
Possible.configuration.of.the.service.ports
Position
Valves.
Double.
valves
3/2-way
5/2-way
2x.3/2-way
6524/6526
6525/6527
6524/6526
1
not used
2
2 (valve 12)
2
2
4
4 (valve 14)
Fig. 17: Possible configuration of the service ports - basic pneumatic module
4.4.
Accessory
Basic.pneumatic.module.-.Accessory
Ident.nr.
Plug to block P-channel
(to build up several pressure levels or medium groups in a AirLINE Ex system type 8650)
655 068
Type 8650
english
Configuration and Function of the
Modules