beautypg.com

Burkert Type 8686 User Manual

Page 38

background image

38

Controlanddisplay

note!

damage or malfunction due to ingress of dirt and moisture.

▶ To comply with degree of protection IP65 / IP67, screw in the

transparent cap / body casing all the way.

Close the transparent cap / body casing (auxiliary tool for
installing the cover: 674077

9)

).

procedure for replacing the diaphragm for type 2036

Voltage is absolutely essential on the device!

Unscrewing the transparent cap makes the service switches
accessible.

Replace the diaphragm as described in the operating instruc-
tions for Type 2036.

After the diaphragm is replaced, perform a reference movement for
spindle adjustment (see “10.3.1 Basic settings”, step 3).

Check that the seal is correctly positioned in the transparent cap
/ body casing (see “Fig. 33”).

note!

damage or malfunction due to ingress of dirt and moisture.

▶ To comply with degree of protection IP65 / IP67, screw in the

transparent cap / body casing all the way.

Close the transparent cap (auxiliary tool for installing the cover:
674077

9)

).

Seal
body casing

Body casing

Type 8686

Fig. 33: Position of the seal in the body casing

9)

The auxiliary tool for installing the cover (674077) is available through
your Bürkert sales office.

English

Type 8685 / 8686