8pneumatic installation – Burkert Type 8686 User Manual
Page 19
19
Pneumaticinstallation
type 2036 actuator 1
actuator 2
cf
connection
cf
connection
D11, D55
CFA/CFA
CFA
2
1
P1
P2: Deaeration
CFA
2
2
P3
P4: Deaeration
D12
CFA/CFB
CFA
2
1
P1
P2: Deaeration
CFB
2
2
P4
P3: Deaeration
D21
CFB/CFA
CFB
2
1
P2
P1: Deaeration
CFA
2
2
P3
P4: Deaeration
D22
CFB/CFB
CFB
2
1
P2
P1: Deaeration
CFB
2
2
P4
P3: Deaeration
Tab. 3: Overview of pneumatic connections for actuator variants
CFA, NC:
Valve closed in rest position (by spring force)
CFB, NO:
Valve open in rest position (by spring force)
For the assignment of control connections see the instal-
lation and dimensional drawing included with delivery of the
valve or in the Type 2036 operating instructions.
8
pneumaTic insTallaTiOn
The dimensions of the feedback head / control head and the different
complete device models, consisting of control, feedback head / control
head, actuator and valve, can be found in the relevant data sheets.
8.1
safety instructions
Danger!
risk of injury from high pressure in the equipment/device.
▶ Before working on equipment or device, switch off the pressure
and deaerate/drain lines.
risk of electric shock.
▶ Before working on equipment or device, switch off the power
supply and secure to prevent reactivation.
▶ Observe applicable accident prevention and safety regulations
for electrical equipment.
Warning!
risk of injury from improper installation.
▶ Installation may only be carried out by authorized technicians
with the appropriate tools.
risk of injury from unintentional activation of the system and
uncontrolled restart.
▶ Secure system from unintentional activation.
▶ Following installation, ensure a controlled restart.
English