Using easy print mode – Datamax-O'Neil microFlash 2te Quick Reference Programming Guide User Manual
Page 38
Using Easy Print Mode
34
Datamax-O’Neil Quick Reference Programming
Configure Bluetooth {CBT:n}
Original
MF2, MF3, 2t, 4t
Radio Ready
2t, 3l, 4t
{
A left bracket begins the command set.
CBT:n
Configures Bluetooth as follows:
A:<string> - Authentication required.
n = Y: Required; n = N: Not required
B:n - Bondable.
n = Y: Bondable; n = N: Not bonadable
C:n - Connectable.
n = Y: Connectable; n = N: Not connectable
D:n - Discoverable.
n = Y: Discoverble; n = N: Not discoverable
E:n - Encryption turned on.
n = Y: Encrypt data; n = N: No encryption
F:n - Friendly name where indicates
the friendly/device name. For example,
{CBT:F:MyPrinter} configures the Bluetooth
friendly name to MyPrinter. You can enter up
to 32 ASCII characters.
I:nnn - Inactivity timeout. Bluetooth
disconnects if there is no Bluetooth traffic in
nnn seconds.
nnn in seconds
default = 180 seconds
minimum = 60 seconds
P:<string> - Specify the passkey.
Note: Some devices with limited keyboard
require a numeric passkey.
Enter up to 16 ASCII characters. The default
passkey is passkey.
S:<string> - Service name. 32 ASCII
characters maximum. Default varies by
printer type.
W: nn - Watchdog timer to check module.
nn in seconds. Default is zero (no check).
Recommended value is 55 seconds. Legacy:
used with older modules only.
X
X
X
X
X
X
X
X
X
X
}
A right bracket ends the command set.