Using Easy Print Mode

32

Datamax-O’Neil Quick Reference Programming

Three-Letter Configuration Commands

TCP/IP 802.llb and Bluetooth Wireless configurations. Versions 5.13 and 6.13 and later only:

Configure Default Values {CDV}
{

A left bracket begins the command set.

CDV

Reverts to non user-specific default values at time of manufacture for

configuration parameters.

}

A right bracket ends the command set.

Restore Default Values {RDV}
{

A left bracket begins the command set.

RDV

Restores all configuration parameters to those stored by the SDV

command.

}

A right bracket ends the command set.

Stores Default Values {SDV}
{

A left bracket begins the command set.

SDV

Stores an image of the current parameter values in separate area of

Flash. See RDV to restore the parameters to those values stored by

SDV.

}

A right bracket ends the command set.