TCP/IP 802.llb and Bluetooth Wireless configurations. Versions 5.13 and 6.13 and later only:
Configure Default Values {CDV}
{
A left bracket begins the command set.
CDV
Reverts to non user-specific default values at time of manufacture for
configuration parameters.
}
A right bracket ends the command set.
Restore Default Values {RDV}
{
A left bracket begins the command set.
RDV
Restores all configuration parameters to those stored by the SDV
command.
}
A right bracket ends the command set.
Stores Default Values {SDV}
{
A left bracket begins the command set.
SDV
Stores an image of the current parameter values in separate area of
Flash. See RDV to restore the parameters to those values stored by
SDV.
}