Figure 5-39 – Atec Tektronix-1502 User Manual
Page 76
TM 9-4935-601-14-3&P
33. Attach Latch Assemblies (2 ea.) to the Front Cover (See Fig. 5-39)
a. COVER, FRONT MPL Item 1-29.
b. LATCH ASSY. MPL Item 1-0.
c. Procedure
1. Clean mating surfaces of Front Cover and Latch Assembly with isopropyl alcohol.
2. Apply No. 3144 sealant to the two screw-holes in each Latch Assembly as shown in Fig. 5-39.
3. Attach the two Latch Assemblies to the Front Cover.
Figure 5-39. Sealing of latch assembly screwholes.
REMINDER: Don't forget to lubricate surfaces of rubber seals around edge of subpanel with G-661 lubricant
before installing instrument in cabinet and attaching front cover.
MATERIALS
Tektronix Part No.
Description
Notes
006-2302-00
Dow Corning No. 3144
This Room Temperature Vulcanizing
Adhesive Sealant
agent (RTV) is used to form water-
tight gaskets. (After application,
006-1171-00
Dow Corning No. 3145
allow 24 hours curing time.)
Adhesive Sealant
252-0199-00
Dow Corning No. 3140
This RTV agent is used where the
Coating
application requires a sealant more
fluid than the No. 3144 sealant.
(Allow 24 hours curing time.)
006-0315-00
Dow Corning No. 4 Sili-
This compound is used in the
cone Dielectric Compound
Battery Pack assembly.
006-2475-00
Dow Corning No. 1204 Primer
Used as a primer for No. 3144 sealant
applications.
006-2207-00
General Electric No. G-661
Used as a waterproof lubricant.
Silicone grease
006-0034-00
Isopropyl Alcohol
Cleaning Agent.
006-2513-00
Econobond #59C
Bonding Material.
REV DEC 1981
5-20