Figure 5-8 – Atec Tektronix-1502 User Manual
Page 65
TM 9-4935-601-14-3&P
NOTE
Failure of the sealant to appear at any point around the retainer is an indication of inadequate sealing.
5. After a curing time of approximately 4 hours, use a small wooden dowel, such as a Q-tip handle, and
remove the excess sealant that is visible between the shield and retainer.
8. Preparation of Front Panel for assembly (see Fig. 5-8)
a. FRONT PANEL MPL Item 2-47.
b. Procedure
1. Clean mating surface of front panel with acetone.
2. Coat mating surface of panel with No. 1204 primer. Allow 2 hours curing time.
9. Bonding of Plug-in Compartment seal to Front Panel (see Fig. 5-9)
a. SEAL, PLUG-IN MPL Item 2-48
b. Procedure
1. Clean mating surfaces of seal with acetone.
2. Apply No. 3144 sealant to mating surface of seal.
3. Position seal on rear side of Front Panel.
Figure 5-8. Front Panel, Identification of Parts For Assembly Step 8 Through 26.
@ FEB 1980
5-9