beautypg.com

E8361a, Test port input – Atec Agilent-E8361A User Manual

Page 40

background image

0

E8361A

Test port input

continued

Description

Specification

Option UNL

Supplemental

Standard or Option 014

and Option 014

information

Third Order Intercept

1

– Tone spacing from 100 kHz to 5 MHz

Typical:

10 to 500 MHz

+0 dBm

500 MHz to GHz

+ dBm

to 0 GHz

+ dBm

0 to 50 GHz

+ dBm

50 to 67 GHz

+6 dBm

Third Order Intercept

1

– Tone spacing from 5 to 20 MHz

Typical:

10 to 500 MHz

Not applicable

500 MHz to GHz

+0 dBm

to 0 GHz

+0 dBm

0 to 50 GHz

+ dBm

50 to 67 GHz

+ dBm

Third Order Intercept

1

– Tone spacing from 20 to 50 MHz

Typical:

10 to 500 MHz

Not applicable

500 MHz to GHz

+6 dBm

to 0 GHz

+ dBm

0 to 50 GHz

+5 dBm

50 to 67 GHz

+7 dBm

System compression level – at maximum leveled output power

See Dynamic Accuracy Chart

Trace noise magnitude

10 to 5 MHz

< 0.150 dB rms

< 0.150 dB rms

5 to 500 MHz

, 5

< 0.010 dB rms

< 0.010 dB rms

1 kHz IF bandwidth

500 MHz to GHz

< 0.006 dB rms

< 0.006 dB rms

ratio measurement, nominal

to 67 GHz

< 0.006 dB rms

< 0.009 dB rms

power at test port

67 to 70 GHz

< 0.006 dB rms

< 0.009 dB rms

Trace noise magnitude

2

– Option 080 enabled

3

10 to 5 MHz

< 0.150 dB rms

< 0.150 dB rms

5 to 500 MHz

, 5

< 0.010 dB rms

< 0.010 dB rms

1 kHz IF bandwidth

500 MHz to GHz

< 0.006 dB rms

< 0.006 dB rms

ratio measurement, nominal

to 67 GHz

< 0.009 dB rms

< 0.01 dB rms

power at test port

67 to 70 GHz

< 0.009 dB rms

< 0.01 dB rms

Trace noise phase

10 to 5 MHz

< 0.800° rms

< 0.800° rms

5 to 500 MHz

5

< 0.100° rms

< 0.100° rms

1 kHz IF bandwidth

500 MHz to GHz

< 0.060° rms

< 0.060° rms

ratio measurement, nominal

to 67 GHz

< 0.100° rms

< 0.100° rms

power at test port

67 to 70 GHz

< 0.100° rms

< 0.100° rms

Trace noise phase

2

– Option 080 enabled

3

10 to 5 MHz

< 0.800° rms

< 0.800° rms

1 kHz IF bandwidth

5 to 500 MHz

5

< 0.100° rms

< 0.100° rms

ratio measurement, nominal

500 MHz to GHz

< 0.060° rms

< 0.060° rms

power at test port

to 67 GHz

< 0.100° rms

< 0.100° rms

67 to 70 GHz

< 0.100° rms

< 0.100° rms

1. Third order intercept is a typical specification that applies while the network

analyzer receiver is in its linear range.

. Typical performance.

. 0 Hz offset.

. Trace noise magnitude may be degraded to 0 mdB rms at harmonic frequencies

of the first IF (8. MHz) below 80 MHz.

5. Specified value is for worst-case noise floor at 5 MHz.