2 intelligent cableups international models – Alpha Technologies XM2, XM2-HV, XM2-HP User Manual
Page 84

6.2 Intelligent CableUPS International Models
The following table shows the electrical, mechanical and physical specifications for the
International models of the Intelligent CableUPS.
XM2 Models:
906HP
906G5
608G5
910
915E
915M
915P
622CE
615CE HP
918HP
Electrical
Input Voltage (Vac):
120/240
115/230
115/230
120/240
190/220/247
100/112/127
190/220/253
230
230
120/240
Input Voltage Window:
-30 to +20%
-30 to +20%
-30 to +20%
-20 to +15%
-20 to +15%
-20 to +15%
-20 to +15%
-20 to +15%
-20 to +15%
-20 to +15%
Input Voltage Window w/ATS:
n/a
n/a
n/a
n/a
-30 to +25%
-30 to +25%
-30 to +25%
n/a
n/a
n/a
Input Frequency:
60Hz
50Hz
50Hz
60Hz
50Hz
60Hz
60Hz
50Hz
50Hz
60Hz
Input Frequency Window:
±3Hz
±3Hz
±3Hz
±3Hz
±3Hz
±3Hz
±3Hz
±3Hz
±3Hz
±3Hz
Output Voltage (Vac):
63/87
63/87
63
63/75/87
63/75/87
63/75/87
63/75/87
63/48
63/48
63/75/87
Output Current (A):
8/6
8/6
8
10/10/10
15/15/15
15/15/15
15/15/15
22/22
15/15
22/18/18
Max Output Power (VA):
540
540
540
900
1350
1350
1350
1350
900
1620
Output Waveform:
Quasi-square wave
Voltage Regulation
1
:
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
Output
Frequency
Stability:
Line Mode
60Hz Nominal
50Hz Nominal
60Hz Nominal
50Hz Nominal
60Hz Nominal
50Hz Nominal
60Hz Nominal
Inverter Mode
60Hz, ±0.05%
50Hz, ±0.05%
60Hz, ±0.05%
50Hz, ±0.05%
60Hz, ±0.05%
50Hz, ±0.05%
60Hz, ±0.05%
Short Circuit Protection:
<150% of maximum current rating
Transfer Characteristics:
Uninterrupted output
Battery Voltage (Vdc):
36
36
36
36
36
36
36
48
36
36
Efficiency
(Typical Load Range)
Line Mode:
80-87%
86-90%
88-92%
Standby Mode:
79-84%
82-85%
84-86%
Battery Charger
Temperature Compensation:
Programmable (0 to 5mV/Cell/°C)
Charger Current:
10A at 80% load and nominal input (bulk charge mode)
Three Stage:
Bulk, Accept, Float
Mechanical
Status Display:
2 x 20 Blue LCD with backlight
Dimensions H x W x D (in/mm):
8.8 x 15 x 13 / 222 x 381 x 330
Approx. Weight (lb/kg):
53/24
62/28.1
62/28.1
62/28.1
82/37.2
70/31.8
70/31.8
82/37.2
70/31.8
72/32.7
Finish:
Black, epoxy powdercoat
Environment
Operating Temperature:
-40 to 55°C / -40 to 131°F
Relative Humidity:
0 to 95% non-condensing
Agency Compliance
FCC Part 15 Class A,
UL1778, UL1012,
CSA 22.2 No. 107.1:
Yes
-
-
Yes
-
-
-
-
-
Yes
CE, EN50083-2, EN62040-2,
EN60950-1, EN62040-1:
-
-
Yes
-
-
-
-
Yes
Yes
-
CB Scheme, IEC 60950-1, EMC
to CISPR22 Class A:
-
Yes
Yes
-
Yes
2
Yes
Yes
3
-
-
-
Optional Features
Standard Protective Interface Module (PIM/N+1): Provides two programmable outputs from a single XM2 CableUPS power supply for redundancy in critical applications. The PIM
protects system components and provides isolation between distribution legs by shutting down the individual load during over-current conditions.
Five Output Protective Interface Module (PIM): Provides four programmable outputs from a single XM2 CableUPS power supply for protection in centralized powering applications. The PIM protects system components and
provides isolation between distribution legs by shutting down the individual load during over-current conditions. An Optical Network Unit (ONU) output is tied to Output 2.
Automatic Tap Switch (ATS): The ATS extends the input AC operating voltage range as indicated above. The ATS is used when a broader input operating range is needed due to utility voltage fluctuations and is currently
available in XM2-915 E/P/M models. Not used in the United States or Canada.
1
Note: Voltage regulation is maintained over both line and load ranges.
2
Note: Certified to CB Scheme and IEC 60950-1.
3
Note: Available only for XM2-915P-CB models.
Table 6-2 Specifications for International Models
84
017-805-B0-010 Rev. K2