beautypg.com

Switcher error responses, Using the command/response tables, Preliminar y – Extron Electronics MTPX Series User Guide User Manual

Page 84: Programmer’s guide, cont’d

background image

Programmer’s Guide, cont’d

MTPX Twisted Pair Matrix Switchers • Programmer’s Guide

4-4

PRELIMINAR

Y

Innn Audxx

]

The switcher initiates the Aud message when a front panel input audio level change

has occurred. nn is the input number and xx is the dB level.
Outnn Volxx

]

The switcher initiates the Vol message when a front panel output audio volume

change has occurred. nn is the output number and xx is the volume level.
Amtnn*x

]

The switcher initiates the Amt message when an audio output mute is toggled

on or off from the front panel. nn is the output number and x is the mute status:

1 = on, 0 = off.
Exen

]

The switcher initiates the Exe message when executive mode is toggled on or off

from the front panel. n is the executive mode: 0, 1, or 2.

Switcher Error Responses

When the switcher receives an SIS command and determines that it is valid, it

performs the command and sends a response to the host device. If the switcher

is unable to perform the command because the command is invalid or contains

invalid parameters, the switcher returns an error response to the host. The error

response codes are:
E01 — Invalid input channel number (too large)

E10 — Invalid command

E11 — Invalid preset number

E12 — Invalid output number (too large)

E13 — Invalid value (out of range)

E14 — Illegal command for this configuration

E17 — Timeout (caused only by direct write of global presets)

E22 — Busy

Using the Command/Response Tables

The command/response table begins on page 4-6. Lower-case letters are acceptable

in the command field except where indicated for the gain and attenuation

commands. The table below shows the hexadecimal equivalent of each ASCII

character used in the command/response table.

ASCII to HEX Conversion Table

Space

Symbols are used throughout the table to represent variables in the command/

response fields. Command and response examples are shown throughout the table.