Relay Contacts

The relay outputs consist of four sets of NO and NC relay contacts. Connect an external
device that you want to be able to switch on or off to the player via three poles (normally
closed [NC], common [C], and normally open [NO]) of the 3.5 mm 4-pole captive screw
connectors.

NOTE: Relays R1 and R4 each span three poles on a single

NC C NO

NC

R1

NC

NC

C

C

C

NO

NO

NO

R3

R4

R2

4-pole captive screw connector. Relays

R2

and

R3

each span two captive screw connectors.

These relay outputs act as switches to control external devices. Their activity is controlled via
MSVPP commands only (see “Applicable MSVPP commands“, below).

Applicable MSVPP Commands

The table below lists the MSVPP commands that you may need to control the inputs
and relays ports. These control functions are available only via MSVPP commands. The
commands sent to each player are the same, whether the show control computer is
connected to Remote port 1 or either LAN port.

NOTE: Click the

blue

links below to see the full command description in the

“Programming Guide“ section, including the complete command syntax,
variables, responses, and some examples.

Command

Function

Digital inputs commands

GetInput <port#>

View the status of one or more inputs.
Poll multiple inputs by separating them with spaces in the command.
If no input is specified, the media player returns the level on all inputs.

SetInputTrigger

On

Set the Digital Inputs ports to automatically report a status change such as a
switch closure.

NOTE: If the input trigger is on, the media player sends an input state message to the connected computer

whenever the state of an input changes. The message is similar to the response to the GetInput
message and contains the current state of all inputs. It is up to the show control system to determine
which input or inputs changed and act accordingly.

SetInputTrigger

Off

Set the Digital Inputs ports to stop reporting status changes.

Digital outputs commands

Setoutput <port> <+ or –>

Set multiple output levels by separating them with spaces ( + = on, – =off).

GetOutput <port>

View the status of one or more outputs/
Poll multiple outputs by separating them with spaces in the command.
If no output is specified, the media player returns the level on all outputs.

JMP 9600 Media Player • Detailed System Interaction