beautypg.com

Switcher-initiated messages, Power-up, Input selection – Extron Electronics ISS 408 User Manual

Page 42: Busy (cut and dissolve), Power-up input selection busy (cut and dissolve)

background image

ISS 408 Integrated Seamless Switcher • Programming Guide

36

Switcher-Initiated Messages

When a local event such as power-up or a front panel operation occurs, the switcher
responds by sending a message to the host. The switcher-initiated messages are listed in
the following pages. The messages are underlined.
The switcher does not expect a response from the host; but the host program may request
a new status.

Power-up

(c)

Copyright

20nn,

Extron

Electronics,

ISS

408

Vx.xx]

The copyright message is initiated by the switcher when it is first powered on.

Vx.xx

is the

firmware version number.

Input Selection

OutX@

InX!

All]

A front panel video and audio switching, cut, or dissolve operation has occurred.

X@

is the

output number and

X!

is the input number.

OutX@

InX!

RGB]

A front panel video-only switching, cut, or dissolve operation has occurred.

X@

is the output

number and

X!

is the input number.

OutX@

InX!

Aud]

A front panel audio-only switching, cut, or dissolve operation has occurred.

X@

is the output

number and

X!

is the input number.

Busy (Cut and Dissolve)

BsyX#]

A cut or dissolve operation has been initiated or completed and the switcher is reporting
its busy status (

X#

). After the switcher has reported that it is busy (Bsy1

]

), it ignores all SIS

commands until it completes the operation and reports that it is no longer busy (Bsy0

]

).

Cutting or dissolving in stay mode

The switcher issues the following reports when you switch the input that is applied to the
preview output to the program output in stay mode:

NOTE: The sequence of commands may vary, but you should see all of the listed

commands.

TkeX$]

(SIS operation response only) The switcher has
received the SIS “Take” (

%

) command.

Bsy

1

]

The switcher is busy and will not respond to any SIS
commands.

Out1

InX!

All

(or

RGB

or

Aud

)

]

The input to the program output has changed (to the
input that

had been switched to preview output).

Bsy0]

The switcher is no longer busy and is able to respond
to SIS commands.