The switcher checks several possibilities, in the following order, and then

responds accordingly:
a

. Does the address include a specific file name, such as 10.13.156.10/file_

name.html? If so, the switcher downloads that HTML page.

b

. Is there a file in the memory of the switcher that is named “index.html”?

If so, the switcher downloads “index.html” as the default startup page.

c

. If neither of the above conditions is true, the switcher downloads the

factory-installed default startup page, “nortxe_index.html” (figure 5-2),

also known as the System Status page.

Status Tab

System Status page

The Matrix 12800 System Status page (figure 5-2) provides an overall view of the

status of the complete matrix switcher system, encompassing all BMEs and their

active replaceable components. The status Web page automatically updates itself

every few seconds to reflect the latest status of the switcher components.

Refresh system status

Select DSVP

Individual BME status

MKP/MCP status

Figure 5-2 — System status page

For each BME, the System Status page shows the status of the primary and

redundant power supplies, the primary and redundant controller, the fans, the

input cards, and the output cards. Components that are operating properly are

indicated in green, failures are indicated in red, and components that are not

installed are indicated in gray. If a component fails or is removed, the display

shows the change in status the next time it updates.