2-7

Matrix 12800 Switchers • Installation

PRELIMINAR

Y

Serial ports

c

Primary and Secondary RS-232/RS-422 ports — For systems consisting of

a single switcher or for BME 0 on a multi-BME system, connect host devices

(such as computers or touch panel control systems) or MCP 1000 remote

control panels (see the MCP 1000 Remote Control Panel User Guide) to the

Primary and Secondary RS-232/RS-422 ports (figure 2-4). These 9-pin D

connectors provide for serial RS-232/RS-422 control of the matrix switcher.

Figure 2-5 shows how to wire the connectors.

Both ports are connected to both controller circuit cards; a redundant

controller is not required to use the Secondary RS-232/RS-422 port.

MCP/MKP COMM

ETHERNET

BME COM

M

IN

OUT

A B C D

E

FPC COM

M

Tx

Rx

Tx

Rx

Tx

Rx

Tx

Rx

SECOND

AR

Y

PRIMAR

Y

Tx

Rx

Tx

Rx

RS 232/422

RS 232/422

3

SECOND

AR

Y

MCP/MKP COMM

ETHERNET

BME COMM

IN

OU

T

A B C D

E

PRIMAR

Y

FPC COMM

Tx

Rx

Tx

Rx

Tx

Rx

Tx

Rx

Tx

Rx

Tx

Rx

RS 232/422

RS 232/422

80

96

112

128

To Secondary

Host System/Device

Serial Port

To Primary

Host System/Device

Serial Port

Male

Connector

1

5

6

9

Figure 2-4 — Connecting host controllers

RS-232 Function

Pin

1

2

3

4

5

6

7

8

9

TX

RX

Gnd

Not used

Transmit data

Receive data

Not used

Signal ground

Not used

Not used

Not used

Not used

RS-422 Function

TX+

TX-

RX+

RX-

Gnd

Transmit data (+)

Transmit data (-)

Receive data (+)

Receive data (-)

Signal ground

Not used

Not used

Not used

Not used

5

1

9

6

Female

Figure 2-5 — RS-232/RS-422 port pinout

After the BMEs have been virtualized, the system can be controlled through

this connection using the PC or other host system that can generate the proper

commands.

The Matrix 12800 Switchers are factory configured for RS-232 control. To use

the switcher under RS-422 control, you must change an internal DIP switch.

See chapter 6, “

Upgrades and Maintenance

” for details.

The default communications rate is 9600 baud. Baud rates of 19.2, 38.4, and

115 are also available. See chapter 6, “

Upgrades and Maintenance

” for details.

If equipped with a redundant controller, the primary and redundant controllers

must be configured for the same communications protocol and transfer rates.