Matrix 12800 Switchers • Installation

PRELIMINAR

Y

f

Primary and Redundant AC Power Input switches — For BME 0 to recognize

all of the BMEs in the daisy chain, BME 0 may not be powered on before the

other BMEs. Rather, turn on BME 0 at the same time or after the other BMEs.

N

During shipment, circuit cards can become dislodged from their edge connectors

during shipment. Reseat all I/O and controller cards before initial power up.
See chapter 6, “

Upgrades and Maintenance

”, for the applicable procedures.

Toggle the Primary AC Power Input switch to the on ( ) position to power up

the BME.

If this BME is equipped with redundant power supplies A and B, toggle the

Redundant AC Power Input switch to the on ( ) position.

g

Power Supplies LEDs — On power up, observe that the +V and -V Primary

LEDs light to indicate that the supplied power is within

tolerance.

If this BME is equipped with redundant power supplies

A and B, on power up, observe that the +V and -V

Redundant LEDs light to indicate that the supplied

power is within tolerance. If the primary A or B

power supply fails, the Primary LEDs go out and the

Redundant LEDs blink to indicate that the redundant B

or A power supply is supplying the load.

h

CPU Status LEDs — On power up, observe that the Primary CPU Status LED

blinks initially to indicate that internal startup

housekeeping is occurring and then, assuming that the

primary controller is the active controller, blinks to indicate

that the primary controller is ready.

If this BME is equipped with a redundant controller

card, observe that the Redundant CPU Status LED blinks

initially and then, assuming that the redundant controller

is the standby controller, lights steadily to indicate that the

redundant controller is ready. If the primary controller fails,

the Primary CPU Status LED goes out and the Redundant

CPU Status LED blinks to indicate that the redundant

controller is the active controller.

N

Both LEDs blink at startup. After startup, the LED for the active controller

blinks and the LED for the standby controller lights steadily.

POWER SUPPLIES

PRIMARY

REDUNDANT

+V -V

CPU STATUS

PRIMARY

REDUNDANT