beautypg.com

Replacing the fuse, Replacing the fuse, Preliminar y – Extron Electronics Matrix 12800 Series User Guide User Manual

Page 105: Upgrades and maintenance, cont’d

background image

Upgrades and Maintenance, cont’d

Matrix 12800 Switchers • Upgrades and Maintenance

6-8

PRELIMINAR

Y

Replacing the Fuse

The primary and redundant AC power circuits are independently fused. The fuses

are accessible on the rear panel of the switcher. If a fuse opens, the associated

primary or redundant power loop shuts down. If this BME does not have

redundant power supplies, the switcher shuts down. Replace the fuse as follows:

1

.

On the rear panel, insert the flat blade end of an Extron Tweeker or small

screwdriver under the tab on the bottom of the fuse holder and gently pry on

the fuse holder until it protrudes from the rear panel (figure 6-6).

Fuse

Figure 6-6 — Fuse replacement

2

.

Pull the fuse holder clear of the rear panel.

3

.

Remove the fuse from the fuse holder.

4

.

If test equipment is available, you can check the fuse.

5

.

Place a new 5A/250V time delay fuse in the fuse holder.

6

.

Slide the fuse holder into the rear panel until it is flush with the panel.