FW: 841013-005/843003-001

Turbidity and Suspended Solids Transmitter

Display Setup

The "Display Setup" menu provides options for language, clock and fac-
tory settings, Modbus parameters and software version display.

1. Press the up/down keys to highlight the required menu line

(here: Display setup) and then press OK to select it.

Specify Main Screen

Data Logger

Password

Set Sensor Name

Converter Setup

Display Setup

Back Select

OK

Login

Activate/deactivate

Change password

Back Select

OK

Set log interval

0010 sec

Back Select >

Data Logger

Set Sensor Name

SuSix1

Back Select

>

Set Sensor Name

Select line

Linie 1 - Sensor name

Linie 2 - Meas.

Linie 3 -

Linie 4 -

Linie 5

Back Select

OK

Specify Main Screen

Converter Setup

Language

Set Clock

Modbus

Factory settings

Display SW version

Back Select

OK

Display Setup

Sensor Calibration

Averaging

Units

mA output

Cleaning

Solid curve

High Alarm

Low Alarm

Sensor error

Status

Factory settings

Service Menu

Back Select

OK

Select line content

Not in use

Meas.

Homogeneity

Solid curve

Clock

Back Select

OK

Password

Type password

0000

Back Select

>

Change password

0000

Back Select

>

Activate

Deactivate

Back Select

OK

Login

Activate/

Deactivate

Change password

SuSix1 [X]

Meas.

FTU

Select Setup

Main Menu

Converter Top Display

SuSix1 [X]

Meas.

FTU

Select Setup

Converter Top Display

Specify Main Screen

Data Logger

Password

Set Sensor Name

Converter Setup

Display Setup

Back Select

OK

Main Menu

SuSix1 [X]

Prim.

mg/l

Second 0.1%

Select Setup

1 - Main menus

Page1

2. Press the up/down keys to highlight the required optione and then

press OK.

Time format

24 hour

AM/PM

Back Select

>

Language

(GB) English

(US) English

Dansk

Deutsch

Español

Français

Italiano

Nederlands

Norsk

Suomalainen

Svenska

Back Select

OK

Cancel

Delete log

Restore default language

Restore factory setting

Back Select

OK

Change device addresse

Device 1

Back Select

OK

Add device

Change device addresse

Remove device

Change controller ID

Back Select

OK

Scanning

Back

Display 841013-002

SW July 14 2007 14:14:03

Language

841513-000

Back

Set clock

Language

Modbus

Factory settings

Display SW version

Add device

Devices found

Device 1

Back Select

OK

Change device addresse

Change device 1

Back Select

OK

Remove device

Device 1

Back Select

OK

Remove device

Language

Set clock

Modbus

Factory settings

Display SW version

Back Select

OK

Display Setup

Change controller ID

1

Back Select

OK

Number of controllers

1

Back Select

OK

Set clock

2007-08-18 10:53:12

Back Select

>

Language

Set clock

Modbus

Factory settings

Display SW version

Back Select

OK

Display Setup

Change controller ID

Susix 1 1.2 g/L

Susix 2

212 mg/L

Back Select Display

Display Overview Menu

Display configuration

2 - Display Setup

Page2

The available options are described in detail on the following pages.