Port logging – SENA SS800 User Manual
Page 65

65
Figure 4-16 Modem configuration
4.2.11. Port Logging
With the port logging feature, the data sent through the serial port is stored to MEMORY, an ATA/IDE
fixed disk card, a SYSLOG server or a mounting point on an NFS server.
Enable/disable port logging
This parameter defines whether to enable or disable the port-logging feature. The factory default
setting is [disabled].
Port log storage location
The port log data can be stored to the Super Series internal memory, an ATA/IDE fixed disk card
inserted in PCMCIA slot, the mounting point on an NFS server or the SYSLOG server. If the internal
memory is used to store port log data, the port log data will be cleared when the Super Series is
turned off. To preserve the serial port log data, set the storage location to be the ATA/IDE fixed disk
card, SYSLOG server or NFS server. To do this, the user must configure the corresponding media in
advance. Unless the media is properly set up, the user will not be able to select a storage location
from the interface.
Port log buffer size
This parameter defines the maximum amount of port log data to be logged. When using internal
memory to store the log data, the total size of the port buffer cannot exceed 3200 Kbytes (i.e. sum of