beautypg.com

Accounts, Operational mode configuration – B&B Electronics 856-14205--29 - Manual User Manual

Page 24

background image

Configuration

19

Once loaded into the device's SNMP memory area, the system prompts the user to reboot

the device to make the new configuration active.

ACCOUNTS

The following are the three levels for CLI or Telnet account access:

User

View status, change own password, and reboot.

Operator

All User privileges mentioned above, plus ability to change settings.

Administrator Operator privileges mentioned above, plus ability to

add/delete accounts and reinitialize the unit to default
settings (cleandb).

OPERATIONAL MODE CONFIGURATION

There are three modes of operation that can be configured through the Serial/Telnet

session: Mode 1, which supports a mixture of tagged and untagged traffic, Mode 2, Extra
tagging and Mode 3, VLAN Filter.

OPERATION MODE 1 – MIXED TAGGED AND
UNTAGGED FRAMES

In this mode, all tagged and untagged frames pass on any given port. Management to

the device can be tagged or untagged.