Loopback testing – B&B Electronics 856-14205--29 - Manual User Manual

Page 13

background image

Configuration

8

port he wants the fault to be reported to, based on which port he wants to be in
control. LFPT allows the fault to be reported down the line, through to the link
partner at the end, such as a switch or a router.

LFPT can be used in addition to setting up SNMP Traps for link up/link down.
LFPT provides a visual way to determine that link is down, and an SNMP Trap
provides a notification of a link down to a designated workstation.

LOOPBACK TESTING

The iMcV-Giga-FiberLinX-III includes Loopback testing functionality. During
loopback testing, management traffic entering the uplink port is still capable of
managing the device. This is selectable form the UNIT screen in a serial/Telnet
session or through iView².

The menu of choices in the CLI includes:

No loopback, normal traffic mode

Loopback Enabled

Loopback, Source/Destination address swap

Loopback, address swap and clear Multicast bit

No learning on fiber or Data ports

The menu of choices in iView² includes:

OFF

ON

On- Address Swap

On-Address swap + Clear MC