Configuration

18

Command

Description

sfpstats

Provides information about the wavelength, serial number,
output power, BER and other information.

unit

Unit global settings, frame size selection. Unit OAM enable must
be enabled for AH and AG to function.

port

Displays the port status and allows changes to port settings,
such as duplex status and speed.

CLEANDB

Entering cleandb reboots the unit with its database cleaned depending on the option

selected. Users are presented with two, sequential options, first to reset all SNMP settings

and, second, to reset all of the unit’s configuration to default. Enabling the first option

presents the second. Resetting the unit to factory default values (option two) will delete

all custom IP and other configurations performed through iView², to reset the unit to the

default configuration.

DOWNLOADING FILES

Firmware and/or saved configuration data for the iMcV-Giga-FiberLinX-III can be

downloaded via a TFTP connection from a central server via TFTP protocol. Initiate this

download via serial configuration or Telnet session. To download a configuration file, type

download and press Enter to be taken to the Download a file screen. This screen

displays the IP Address of the TFTP server and the name of the file to be downloaded:

The TFTP server should be open. Press Enter to start downloading the file.

After the transfer process is complete, press Enter to load the configuration file: