C/spi interface, Pin description – Rainbow Electronics MAX1386 User Manual
Page 15

MAX1385/MAX1386
Dual RF LDMOS Bias Controllers
with I
2
C/SPI Interface
______________________________________________________________________________________
15
Pin Description
PIN
NAME
FUNCTION
1
DGND
Digital Ground
2
SAFE1
Safe Status Channel 1 Output. Programmable active-high or active-low. SAFE1 asserts when
programmed channel 1 temperature threshold or current threshold has been reached.
3
A0/
CSB
I
2
C-Compatible Address 0/ SPI-Compatible Chip Select. See the Digital Serial Interface section. In
SPI mode, drive A0/
CSB low to select the device.
4
CNVST
Active-Low Conversion-Start Input. Drive
CNVST low to start a conversion (clock modes 01 and 11).
Connect
CNVST to DV
DD
when initiating conversions through the serial interface (clock mode 00).
5
SEL
Mode Select. Connect SEL to DGND to select I
2
C mode. Connect SEL to DV
DD
to select SPI mode.
6
ALARM
Alarm Output. Program ALARM for comparator or interrupt output modes (see the Alarm Modes
section). Program ALARM to assert on any combination of channel temperature or current
thresholds.
7
SAFE2
Safe Status Channel 2 Output. Programmable active-high or active-low. SAFE2 asserts when
programmed channel 2 temperature threshold or current threshold has been reached.
8, 19, 25, 28,
35–39, 42, 46
N.C.
No Connection. Not internally connected.
9
REFDAC
DAC Reference Input/Output
10
REFADC
ADC Reference Input/Output
11
DXP1
Diode Positive Input 1. Connect to anode of temperature diode or the base and collector of an npn
transistor.
12
DXN1
Diode Negative Input 1. Connect to cathode of temperature diode or the emitter of an npn transistor.
13
DXP2
Diode Positive Input 2. Connect to anode of temperature diode or the base and collector of an npn
transistor.
14
DXN2
Diode Negative Input 2. Connect to cathode of temperature diode or the emitter of an npn transistor.
15
ADCIN1
ADC Input 1
16
ADCIN2
ADC Input 2
17
PGAOUT2
Programmable-Gain Amplifier Output 2
18
AV
DD
Analog Power-Supply Input
20, 21, 22
AGND
Analog Ground