Er (see table 68) – Rainbow Electronics T89C5121 User Manual
Page 94

94
A/T8xC5121
4164G–SCR–07/06
Table 68. BDRCON Register
BDRCON
Baud Rate Control Register (9Bh)
Reset Value = XXX0 0000b
7
6
5
4
3
2
1
0
-
-
-
BRR
TBCK
RBCK
SPD
SRC
Bit
Number
Bit
Mnemonic
Description
7
-
Reserved
The value read from this bit is indeterminate. Do not set this bit
6
-
Reserved
The value read from this bit is indeterminate. Do not set this bit
5
-
Reserved
The value read from this bit is indeterminate. Do not set this bit.
4
BRR
Baud Rate Run Control bit
Clear to stop the Baud Rate.
Set to start the Baud Rate.
3
TBCK
Transmission Baud rate Generator Selection bit for first UART
Clear to select Timer 1 for the Baud Rate Generator.
Set to select internal Baud Rate Generator.
2
RBCK
Reception Baud Rate Generator Selection bit for first UART
Clear to select Timer 1 for the Baud Rate Generator.
Set to select internal Baud Rate Generator.
1
SPD
Baud Rate Speed Control bit for first UART
Clear to select the SLOW Baud Rate Generator when SRC = 1.
Set to select the FAST Baud Rate Generator when SRC = 1.
0
SRC
Baud Rate Source select bit in Mode 0 for first UART
Clear to select F
OSC
/12 as the Baud Rate Generator.
Set to select the internal Baud Rate Generator.