beautypg.com

2 types and versions, 1 two instrument series, 2 type survey – VEGA VEGAPULS 81 User Manual

Page 8

background image

8

VEGAPULS 64 and 81

Types and versions

2 Types and versions

2.1 Two instrument series

The two instrument series are generally identi-

cal in their function and efficiency as well as in
the shape of their antenna systems. However

the housing construction, the materials used

and their electronic construction are different.

An indicating instrument with analogue and
digital indication is optimally mounted in the

sensors of VEGAPULS 81 series.

2.2 Type survey

VEGAPULS 64

VEGAPULS 81 F

VEGAPULS 81 D

FV DV FK

DK A B C D E A B C D E

Measuring range 0 … 20 m,

- optionally 35 m (on request)

Output signal

- 0 … 20 mA analogue

- digital

Supply and output signal

- via a two-wire line

- separately via

2 two-wire lines

- via a four-wire line

Ex Zone 0 approved

StEx Zone 10 approved

Classification
- supply EEx…

i

e

e

e

e

i

e

e

e

e

- output signal EEx…

i

e

e

e

i

i

e

e

e

i

- circuit for external indicating

instrument VEGADIS 10 Ex

i

i

i

i

i

i

i

i

i

i

Housing made of

- plastic

- powder-coated Aluminium alloy

VEGAPULS

64 F…

64 D…

VEGAPULS

81 F…

81 D…