6.4 Adjustment with signal

conditioning instrument

In general the radar sensors are adjusted with

the PC and the adjustment software VVO.

Radar sensors with digital signal output how-

ever can be also adjusted with the adjustment

and indication module of the signal condition-
ing instruments VEGAMET 514 V or 515 V,

however not the sensors with 0 … 20 mA-

signal output (compact instruments).

Set-up

Sensors with digital output signal are con-

nected with a two-wire cable to a signal condi-

tioning instrument VEGAMET 514 V or 515 V or

to the processing system VEGALOG 571. Via

this two-wire line also the communication with
the sensor is transmitted beside the power

supply and the measuring signal.

The adjust with the adjustment module the

signal conditioning instrument and the con-
nected radar sensors.

Indication and adjustment module of a signal conditioning instrument VEGAMET
513 … 515

ESC

OK

+

1

2

on

100

%

CONNECT

515 V

Acc. to the parameter, change value or

select out of list

Select menu point parameter or shift
flashing cursor

Acc. to the menu point, save the

adjusted value or go to the lower menu

Branch, i.e. jump into the lower

menu with [OK]

Acc. to the menu point, cancel

adjustment or jump into the

upper menu

Display,

indication of
- measured value

- menu point

- parameter
- value

Analogue LED-indication

(0 … 100 %)