VEGA VEGAPULS 81 User Manual
Page 20
20
VEGAPULS 64 and 81
Technical data
Error limits
Linearity error
< 0,1 %
Temperature drift
0,015 %/10 K
0 … 20 mA current output of the
compact instruments (DA-converter)
0,025 %
Characteristics
Frequency
5,8 GHz (USA 6,3 GHz)
Intervals
0,1 s
Resolution
1 mm
Min. span (min/max adjustment)
- analogue output signal
10 mm
- digital output signal
5 mm (50 mm at a measuring range > 32 m)
Beam angle (at –3 dB)
- horn antenna
DN 100
30
°
DN 150
20
°
DN 250
14
°
- rod antenna
24
°
Ambient conditions
Vessel pressure
- general
0 … 16 bar
- option
0 … 64 bar
- PP-flange (VEGAPULS 64)
0 … 0,5 bar
- StEx Zone 10 (VEGAPULS 64)
0 … 1,15 bar
Ambient temperature on the housing
- VEGAPULS 64
-30
°
C … +60
°
C
- VEGAPULS 81
-30
°
C … +65
°
C (non-Ex-area)
-20
°
C … +60
°
C (Ex-area)
Flange temperature
- types F…
-40
°
C … +150
°
C
- types D…
-100
°
C … +200
°
C
- PP-flange (VEGAPULS 64)
-40
°
C … +80
°
C
- option (with cooling facility)
more than 1000
°
C (product temperature)
Storage and transport temperature
-40
°
C … +80
°
C
Protection
IP 67
Protection class
I
Overvoltage category
III
Self-heating VEGAPULS 64… StEx
at an ambient temperature of 40
°
C
StEx-instruments reach 45
°
C on the flange and
55
°
C on the housing.