beautypg.com

VEGA VEGAPULS 81 User Manual

Page 15

background image

VEGAPULS 64 and 81

15

Types and versions: Configuration of measuring systems

Measuring system with 1 … 5 VEGAPULS 81 sensors (type B) per
two-wire line on the processing system VEGALOG 571

• Digital output signal; signal processing in the processing system.

• Up to five sensors on one two-wire line; 15 sensors (in three groups with five sensors each) on

one input card. The two-wire line transmits the power supply, the digital output signal as well

as the superimposed adjustment signal.

• Approved in Ex Zone 0, supply/output signal in EEx e (increased safety).
• Adjustment and parameter adjustment via a PC and the adjustment program VVO. The PC is

directly connected to the computer module of the processing system via an interface cable

(RS 232).

• An indicating instrument with digital and analogue indication is optionally integrated in the

sensor.

• Optionally an external digital/analogue indication. The indication can separated from the sen-

sor in Ex zone 0 up to 25 m.

• The max. permissible resistor of the two-wire signal and supply line is 15

per wire or max.

1000 m cable length between processing system and sensor.

VEGALOG

571 CPU

VEGALOG

571 EV

2

2

2

2

2

4

4

2

CPU

Current outputs

Voltage outputs

Relay outputs

Transistor outputs

Fail safe outputs

Indication outputs

Digital connectability
Connection to all BUS-systems

Outputs (see also Product
Information “Processing

system VEGALOG 571“)

VEGADIS 10

Processing system

VEGALOG 571 with input
cards in 19“-rack, up to 15

sensors (3 x 5) per card

VEGACONNECT

VEGAPULS 81 with digital

signal output, up to 5 sensors
on one two-wire line

PC with adjustment software
VEGA Visual Operating

Screened cable for strong electro-

magnetic interferences

Ex-area

Non-Ex-area

EEx i

EEx e

EEx i

EEx e

EEx i