beautypg.com

VEGA VEGAPULS 81 User Manual

Page 52

background image

52

VEGAPULS 64 and 81

Electrical connection: Connection diagram VEGAPULS 81

VEGAPULS 81 FA and VEGAPULS 81 DA, digital output signal (VBUS) EEx ib

Supply and output signal via separator intrinsically safe on a four-wire line.

VEGAPULS 81 FB and VEGAPULS 81 DB, digital output signal (VBUS) EEx e

Up to five sensors with supply and output signal in EEx e on one two-wire line.

VEGAPULS 81 FC and VEGAPULS 81 DC, digital output signal (VBUS) EEx e

Separate supply, up to 15 sensors with their output signal (VBUS) on one two-wire line, two-wire

line of the supply and two-wire line of the signal output in "e".

5 6 7 8

1 2 3 4

+5V

SCL GND

SDA

+ – + –

4

3

2

1

+

+

– z30
+ z32
– d32
+ d32

– 4
+ 3
– 2
+ 1

5 6 7 8

1 2 3 4

+5V

SCL GND

SDA

U+

U-

4

3

2

1

+

5 6 7 8

1 2 3 4

+5V

SCL GND

SDA

U+

U-

+ –

4

3

2

1

+

+

for optional
external

indication
(VEGADIS 10)

for optional

external
indication

(VEGADIS
10)

for optional

external
indication

(VEGADIS
10)

20 … 36 V DC

20,5 … 26,5 V AC

90 … 250 V AC

Digital output signal

(VBUS) to the signal

conditioning instru-
ment VEGAMET or

VEGALOG

Supply and digital

output signal (VBUS)
from and to the

signal conditioning

instrument
VEGAMET or

VEGALOG

Supply and digital
output signal

(VBUS) from
separator

VEGATRENN 547

or

from safety barrier

type 146 or
VEGATRENN 546

(ia)

(ib)

(ia)

(e)

(ia)

(e)

(e)