beautypg.com

VEGA VEGAPULS 81 User Manual

Page 36

background image

36

VEGAPULS 64 and 81

Mounting and installation: Measurements of liquids

Rod antenna on DIN-socket piece

Rod antenna directly on vessel opening

150 mm

Opening

ø 50 mm

Mounting directly on the flat vessel ceiling

Reference pane

Horn antenna directly on the vessel ceiling

Dependent on the stability of the vessel (sen-

sor weight), the flat mounting directly on the

vessel ceiling would be a good and favourable

solution. The top side of the vessel is the refer-

ence pane.

Rod antenna

Rod antenna on DIN-socket piece

The PTFE (Teflon) rod antenna is especially

used in aggressive products such as lyes and

acids. Applications in the food processing

industry with aseptic vessels require reaction
neutral measuring systems often with smaller

vessel openings. The teflon rod antenna is not

only reaction neutral but can be also mounted

to very small vessel openings with 50 mm

access.

For measurements of liquids with the Teflon

rod antenna, the mounting is made on a

straight DIN-socket piece. The socket however

must not be longer than 150 mm (when using
a longer antenna, not longer than 250 mm).

The rod antenna is available in flange sizes of

DN 50, DN 80, DN 100 and DN 150.

Rod antenna directly on vessel opening

Alternatively to the socket mounting, the rod

antenna can also mounted directly to the
circular vessel opening (holes).

Note that the mechanical load of the PTFE-rod

antenna is restricted. If the antenna is sub-

jected to lateral power, their will be danger of
deformation or break.