beautypg.com

VEGA VEGAPULS 81 User Manual

Page 39

background image

VEGAPULS 64 and 81

39

For reasons of the radar signal polarization the
holes and slots must be positioned in two rows

displaced by 180

°

.

The mounting of the radar sensor is then such

that the type plate of VEGAPULS 64 or the
casting nose of VEGAPULS 81 is in one axis

with the rows of holes.

Surge pipe with stop valve

When using a stop valve in the surge pipe, it is

possible to carry out maintenance and service

work without opening the vessel (e.g. with

liquid gas or toxic products).

Requirement for an interference free operation

is a ball valve outlet corresponding to the pipe

diameter. The ball valve must not have any

coarse edges or throats in the outlet against

the measuring pipe.

VEGAPULS 64: Row of holes in one axis with
the type plate

Lockable measuring pipe on a pipe antenna

system

VEGAPULS 81: Row of holes in one axis with

the casting nose

Type plate

Casting nose

DN 50

ø50

Ball valve

Breather hole

Mounting and installation: Measurements of liquids