beautypg.com

3 technical data, 1 technical data – VEGA VEGAPULS 81 User Manual

Page 19

background image

VEGAPULS 64 and 81

19

Technical data

3 Technical data

3.1 Technical data

Power supply

VEGAPULS 64…

Supply voltage

(with separate supply)

16 … 36 V DC; 20,4 … 26,4 V AC
110, 130, 230 V AC; –15 % … 10 %

max. current consumption

160 mA

max. power consumption

3,6 W, 4 VA

VEGAPULS 81…

Supply voltage
(with separate supply)

24 V DC (20 … 36 V DC)

24 V AC (20,4 … 26,4 V AC)

90 … 250 V AC

max. current consumption

200 mA

max. power consumption
-type A, B, C

3,6 W, 11 VA

- type D, E

4,5 W, 13 VA

Measuring range

Standard

0 … 20 m

Option

0 … 35 m

Measurement in surge or bypass pipe
- DN 50

0 … 16 m

- DN 100

0 … 19 m

Option

- DN 50

0 … 28 m

- DN 100

0 … 33 m

Output signal

VEGAPULS 64
- type …V…

digital measuring signal (VBUS)

- type …K…

0 … 20 mA-current signal, load max. 500

VEGAPULS 81

- type A, B, C

digital measuring signal (VBUS)

- type D, E

0 … 20 mA-current signal, load max. 500

Ex-technical data VEGAPULS 81

Temperature class

ambient temperature on the antenna system in

Ex-areas

- T6

85

°

C

- T5

100

°

C

- T4

135

°

C

- T3

150

°

C (with temperature adapter 200

°

C)

Classification

- type A

EEx d ia [ia] II C T6 (supply in “ib“)

- type B, C, D and E

EEx d e ia [ia] II C T6

Approved for gas group

IIC