Ranger RP

37

4.3.10

RESET – resetting scale settings to factory settings

4.4 Application settings (APPLICATION)

4.4.1

COUNT – settings for counting

SUrE?

Confirmation inquiry

Reset the scale settings to factory settings with

Yes

Do not reset scale settings with

No

VAr-SPL

Adaptation of the reference quantity

ON

The reference quantity can be changed in operating mode

OFF

Counting only with defined reference quantities

Min.reFW

Monitoring the minimum reference weight

OFF

No monitoring of the minimum reference weight

97.5, 99.0,

99.5

Monitoring the minimum reference weight so that a counting accuracy of
97.5 %, 99.0 % or 99.5 % is achieved

rEF.OPt

Optimizing the average piece weight

OFF

No reference optimization

AUtO

Automatic reference optimization

A-SMPL

Automatic determination of the average piece weight

ON

After taring, the average piece weight is determined with the next weight placed
on the scale and the displayed reference quantity

OFF

No automatic determination of the average piece weight

A.CL-APW

Automatic clearing of the average piece weight

ON

When the load is taken off the scale after a counting operation, the average piece
weight is automatically cleared. The next counting operation begins with deter-
mining the average piece weight again.

OFF

The average piece weight must be cleared manually by pressing

C

ACCurCY

Displaying the counting accuracy

ON

After the average piece weight is determined, the counting accuracy that can be
achieved is shown briefly in the display.

OFF

No counting accuracy display

tOtAl.Ct

Counting on two scales

bULK

Display number of pieces for the parts on the bulk scale only

bOth

Display number of pieces for all parts on the bulk and the reference scale