5 reference optimization, 1 automatic reference optimization, 6 counting with automatic reference determination – Ohaus RANGER ADVANCED COMPACT COUNTING SCALES Manual en User Manual
Page 24: 7 counting with a known average piece weight, Reference optimization, Counting with automatic reference determination, Counting with a known average piece weight

Ranger RP
24
Counting
3.5 Reference optimization
The greater the reference quantity, the more accurately the scale determines the
number of pieces.
3.5.1
Automatic reference optimization
rEF.OPt -> AUtO must be set in the menu for this. The symbol Auto Opt appears
in the display.
1. Place the reference parts on the scale and press
Sample 10
or
Sample Size
.
2. Place additional reference parts, max. the same number as for the first reference
determination, on the scale.
The scale automatically optimises the average piece weight with the larger number
of reference parts.
The rest of the counting process is as described earlier.
Note
The reference optimization can be performed several times.
3.6 Counting with automatic reference determination
Prerequisite
A-SMPL ON is set in the menu.
➜
Place the number of pieces displayed
above the key
Sample Size into the
container.
The scale automatically determines the average piece weight and then shows the
quantity.
The rest of the counting process is as described earlier.
3.7 Counting with a known average piece weight
➜
Enter the known average piece weight
via the numerical keypad and press
Manual
Set.
The scale changes the unit to PCS.