3.8 Counting by calling up a saved average piece weight
The compact scales Ranger RP have a
total of 100 memory locations for frequently
used tare values, average piece weights, target weights and target quantities.
In the factory setting, the memory locations 41 to 80 are reserved for average piece
weights. The saved average piece weights are also preserved when the scale is
switched off.
3.8.1
Saving average piece weights
1. Determine the average piece weight in one of the ways described earlier.
2. Enter the memory location number (factory setting: 41 ... 80) and keep
Mem
pressed until the confirmation appears in the display, e.g. APW.41.
Note
If an average piece weight had already been saved under the selected memory loca-
tion, the message rEPLACE appears in the display.
•
To save the new average piece weight, press
Yes
. The old average piece weight
is overwritten.
•
To abort the save process, press
No
. The pre
vious memory location assignment
remains valid.
3.8.2
Calling up average piece weights
Enter the number of the memory location with the required average piece weight
(factory setting: 41 ... 80) and press
Mem briefly.
The selected reference value is loaded from the memory and appears briefly in the
display. The scale determines the number of pieces with the selected reference
value.
3.8.3
Clearing saved average piece weights
1. Enter the number of the memory location with the average piece weight to be
cleared (factory setting: 41 ... 80) and press
Mem
briefly.
The saved average piece weight is displayed.
2. Press
C
within 2 seconds.
CLEArED briefly appears in the display. The saved average piece weight is
cleared.