beautypg.com

ACU-RITE VRO 300T User Manual

Page 59

background image

Troubleshooting

VRO 300T

52

Check fuse.

With the power cord removed, use a thin straight-blade

screwdriver to remove the cover of the electrical input module. Slide out
the fuse holder and check the fuse. If necessary, replace it. Replace the
input module cover by snapping it back into place, and reconnect the
power cord.

Incorrect Operation

If system positioning does not seem to be repeatable, the problem could be
with the machine tool or with the readout system.

Check the machine tool.

Check that the saddle is not locked. Ensure that

the turret-to-column bolts are properly secured. Check the gib
adjustments. Check spindle run-out.

Check linear encoders.

Check each encoder and reading head for proper

installation. Ensure that the mounting brackets are secure.

!

CAUTION

Replace fuses only with the specified type. Using incorrect fuses
can present a safety hazard. The readout may also be
permanently damaged. Refer to the Readout Specification chart
on page 50 for the correct fuse.

Opening

slot

This manual is related to the following products: