VRO 300T

Program Operations

19

Position Steps

This step lets you program a positioning move. You can preset up to four axes

at once. The dimension in each axis can be absolute or incremental.

P

OINT

—press an axis key to specify which

direction you wish to move. Enter the

dimension. If the dimension is incremental,
press the

ABS

INCR

key and enter the number of

the step you want to reference. The
reference step must precede the current step
in the program.

Use the arrow keys or the

ENTER

key to

move from one axis to another.

Example

POSITION

003

POINT

X

Z1

ABS

INCR

1.000

1.250

002

3.00

1.00

DIA

1.50

DIA

1.25

Absolute Zero

1.50 DIA

3.00

Incremental Zero,

position step 002

1.0

DIA

1.25

Incremental Zero,

position step 003

This becomes Step 002. It will be
the reference step for Step 003.

.

1

2

ABS

INCR

ENTER

POS

Z1

X

1

.

0

USE

5

2

This becomes Step 003. Notice that the Z
dimension is measured incrementally from
Step 002.

We’ll use 2 Position Steps to make
this part. This example assumes
that the X axis reads in diameter
and that Step 001 is a tool step.

3

+/-

.

ENTER

POS

Z1

X

1

.

5

USE

0

This manual is related to the following products: