beautypg.com

Presetting – ACU-RITE VRO 300T User Manual

Page 20

background image

VRO 300T

Readout Operations

13

Presetting

When you preset a dimension, the readout places an incremental zero at the

location you specify. Then, the display automatically switches to the
incremental display so you can move to zero.

Begin a preset by pressing an axis key (

X

for

example). The information from the previous
preset will appear. The display will show you if the
preset is absolute or incremental. Use the

ABS

INCR

key

to change from one to the other. Enter the

dimension you want to preset.

-1.625

Absolute Zero

Z 0.000 ABS

The tool is at 0.000 ABS.

To preset the absolute location of the shoulder:

Z1

2

5

ENTER

6

.

1

+/-

1.625

Now the tool is

1.625 on the

positive side of the

shoulder.

Z 1.625 INCR

ABS

INCR

Z 0.000 ABS

Incremental zero: the

incremental display

will read 0.000 when

the tool is at this

point.

Display automatically

switches to incremental.

Absolute display reads zero.