beautypg.com

ZyXEL Communications Prestige 480 User Manual

Page 211

background image

Prestige 480 Dual BRI ISDN Router

Backup, Restore and Upload

14-11

Step 3. Enter the administrator password. The default is 1234

Step 4. Enter the command “bin” to set binary transfer type

Step 5. Use the command “put” to transfer files between the Prestige and the workstation. The file name

for the firmware is “ras” and for the configuration file “rom-0” (rom-zero, not capital o).

Figure 14-11 FTP Example

The system reboots after a successful upload.

Using FTP client software

Step 1. Rename the local firmware and configuration files to 'ras' and 'rom-0', because we can not

specify the remote file name in the FTP client software.

Step 2. Use FTP client from your workstation to the Prestige 480 and log in by entering the IP address of

the Prestige.

Step 3. Set the transfer type to 'Auto-Detect' or 'Binary'.

Connected to 480.x.x.x

220 P480 FTP version 1.0 ready at Thu Jan 8 18:00:02 1970

User (480.x.x.x:(none)):

331 Enter PASS command

Password:

230 Logged in

ftp> bin

ftp> ha